Venting Products Double Wall Gas Vent Connectors
Die formed from heavy gauge galvanized steel for uniformity and strength. Ease of Assembly
Lengths of B-Vent model BVS (3" - 8") and BVM (10" - 14") are joined by inserting mating ends together and twisting clockwise to lock. To
disassemble simply twist the upper section counter clockwise and lift. The Venting Action of B-Vent
The venting action derives from the aluminum vent liner which heats quickly and evenly and from the 1/2" annular air space, maintained uniformly by the connector rings, which act as insulators, thereby
preventing undue heat loss and eliminating corrosive condensation within the vent. Expansion and contraction from heating and cooling of the aluminum causes no ticking or banging because the liner is not
fastened to the rest of the vent, but held in place by the connector rings.
Insulated B-Vent (4" to 14" diameter) Insulated B-Vent has a 1/2" blanket of fibreglass insulation between the aluminum liner and the galvalume case. This insulation substantially maintains the flue gas temperature over standard air insulated
B-Vents. This type of B-Vent is used where runs must be made through cold areas, such as up the outside wall of a structure, or for longer than average heights above a roof where cold conditions could lead to
condensation problems.
Use of B-Vent
B-Vent is used for venting approved gas appliances in accordance with the Installation Code for Gas Burning Appliances and Equipment, CSA B149.1 and CSA B149.2 in Canada, and the Standards for Gas Piping
and Gas Appliances in Buildings, and NFPA No. 211 in the U.S.A., and as permitted by the authority having jurisdiction. These vents must not be used for venting incinerators, appliances required to be
connected to chimneys or appliances operating under forced draft.
Testing and Approval
Model BVS (3" - 8"), BVM (10" - 14") and BVL (16" - 30") have all been tested by ULC and UL in their laboratory and found to comply with all
criteria of their labelling service which is backed by periodic ULC and UL factory inspections. Results of the tests are available upon request.
Pellet Pipe and Fittings ULC and UL listed for use with Pellet Stoves Chimney Liners Flexible Aluminum Chimney Liner Kits Don Park liner kits are available in two styles to suit the HVAC and Fireplace Installer needs.
Model FCLK*HV Contains
Model FCLK*EX Contains
Model FLCK*FP Contains
Optional heavy duty connector
Rigid Aluminum Chimney Liners Rigid Stainless Steel Chimney Liners Stainless Steel Wind-Activated Directional Revolving Vent
|
||